Skip to content

Language

SKU USB-RLY02

2 Channel USB Relay Module

Original price €34,81 - Original price €34,81
Original price
€34,81
€34,81 - €34,81
Current price €34,81

All prices are VAT included

Availability:
Out of stock
Availability:
On order
Request Quantity Discount and Information

PRODUCT DISCONTINUED, REPLACED BY THE NEW VERSION


The USB-RLY02 provides two volt free contact relay outputs with a current rating of up to 16Amp each. The USB-RLY02 is powered and instructed by any standard USB bus and does not require any additional power. The relays are SPCO (Single Pole Change Over) types. The normally open, normally closed and common pins are all available on the screw terminals.

LED indication
The USB-RLY02 provides a red LED mounted immediately next to each relay to indicate whether it is in a powered state (LED on).

Relay power rating
If the contact load voltage and current of the relay are in the region below the solid line in the figure below, the relay can perform stable switching operation. If the relay is used at a voltage or current exceeding this region, the life of the contacts may be significantly shortened.

load type Typical applications Rating Max DC load capacity

AC1 Not inductive or
slightly inductive loads
16A @ 250V AC
AC15 Control of
electromagnetic load
(>72VA)
3A @ 120V AC
1.5A @ 240V AC
AC3 Control of motor 750W
DC1 Not inductive or
slightly inductive loads
16A @ 24V DC
DC13 Control of electromagnetic
loads
0.22A @ 120V DC
0.1A @ 250V DC

A full datasheet for the relays used on the RLY02 is here: RM85 datasheet

First Step - Install the Driver
The USB-RLY02 module uses the Microchip PIC24FJ32GB002 to handle all the USB protocols. Before using the USB-RLY02, you will need to download the Devantech inf files and unzip them into a temporary folder. Connect the RLY02 and windows will detect it and ask for the drivers. Point windows to the inf folder and it will install the driver. The RLY02 will now appear as a port.

Which COM port?
After installing the drivers, and plugging in the USB-RLY02 module to a spare USB port, you will want to know which COM port it has been assigned to. This will vary from system to system depending on how many COM ports you currently have installed. To find out where it is, right click on your "My Computer" desktop icon and select the "Device Manager" tab. Now scroll down and open the "Ports (COM & LPT)" tab. You should see the USB serial port listed - COM2 in the example below. If you want to change the COM port number - just right click on it, select properties, select advanced and select the COM port number from the available list. The COM port may be left at the default baud rate etc, because they are not actually used - there is a direct USB connection into the processor.

Commands
The USB-RLY02 operates with an easy to use command set as described in the table below. Most commands are only a single byte and if applicable the USB-RLY02 will automatically send its response. The only exception to this being the "Set relay states" command which requires and additional desired states byte to be sent immediately after the command byte.

Command

Action

dec hex
90 5A Get software version - returns 2 bytes, the first being the Module ID which is 10, followed by the software version
91 5B

Get relay states - sends a single byte back to the controller, bit high meaning the corresponding relay is powered

ninety two 5C Set relay states - the next single byte will set all relays states, All on = 3 (xxxxxx11) All off = 0
100 64 All relays on
101 65 Turn relay 1 on
102 66 Turn relay 2 on
110 6E All relays off
111 6F Turn relay 1 off
112 70 Turn relay 2 off

Board dimensions

Test program
To get the USB-RLY02 up and running in the minimum amount of time we have put together a RelayTest program to demonstrate the functionality of the module.