Salta il contenuto

Lingua

SKU 808245

Maynuo DC Load - M9711 150W 0-30A 0-150V

Esaurito
Prezzo originale €610,00 - Prezzo originale €610,00
Prezzo originale
€610,00
€610,00 - €610,00
Prezzo attuale €610,00

Tutti i prezzi sono IVA inclusa

Disponibilità:
Esaurito
Richiesta Sconto per Quantita' e Informazioni

-Six high speed operation modes: CC,CR,CV,CW,CC+CV,CR+CV
-Over current, over voltage, over power, over heating and polarity reversal protection 
- High-luminance vacuum fluorescent display (VFD) screen with two line, four channel display
-Intelligent fan system will automatically activate based on changing ambient temperatures
-Soft-start time setting, activating the power supply in accordance with the set voltage value 
-Battery test and short-circuit test functions
-Capable of rising edge and falling edge dynamic testing
-Supporting external triggeron either input or output
-External current waveform monitor terminal output terminal
-Supports remote voltage compensation and multi-data storage
-Power-on-self-test, software calibration and standard rack mountable
-Edits arbitrary waveforms in list function
-Available with RS232/RS485/USB serial interfaces.

 

Application:

M97XX series have wide application from production lines for cell phone chargers, cell phone batteries, electronic vehicle batteries, switching power supplies, linear power supplies, and LED drivers, to research institute, automotive electronic, aeronautic and astronautic, maritime, solar celland fuel cell etc.test and measurement applications.

Specification:

Model M9711
Input Rating Power 150W
Current 0-30A
Voltage 0-150V
CC Mode Range 0-3A 0-30A
Resolution 0.1mA 1mA
Accuracy 0.03%+0.05%FS 0.03%+0.05%FS
CV Mode Range 0.1-19.999V 0.1-150V
Resolution 1mV 10mV
Accuracy 0.03%+0.02%FS 0.03%+0.02%FS
  CR Mode   (Voltage and current input value >=10% full measurement) Range 0.03-10K Oh 0.03-5K Oh
Resolution 16 bit 16 bit
Accuracy 0.1%+0.1%FS 0.1%+0.1%FS
  CW Mode  (Voltage and current input value >=10% full measurement) Range 0-150W 0-150W
Resolution 1mW 10mW
Accuracy 0.1%+0.1%FS 0.1%+0.1%FS
Voltage Measurement Voltage 0-19.999V 0-150V
Resolution 1mV 10mV
Accuracy 0.015%+0.03%FS 0.015%+0.03%FS
Current Measurement Current 0-3A 0-30A
Resolution 0.01mA 0.1mA
Accuracy 0.03%+0.05%FS 0.03%+0.08%FS
Power Measurement(Voltage and current input value >=10% full measurement) Power 100W 150W
Resolution 1mW 10mW
Accuracy 0.1%+0.1%FS 0.1%+0.1%FS
Battery Test

Battery Input: 0.1-150V;  Max. Mesurement:Capacity=999AH;   Resolution=0.1mA;      Test Range=1S-16H

Dynamic Test

Transition List:0-25kHZ; 2.5A/uS; T1&T2:60uS-999S; Accuracy:+15% offset+10%FS

Current soft-startup Time

1mS;2mS;5mS;10mS;20mS;50mS;100mS;200mS;500mS;1000mS           Accuracy:+15% offset+10%FS

Short Circuit Current(CC) =3.3A =33A
Voltage(CV)  0V
Resistance(CR) =55mOh
Temperature Operating 0~40oC
Nonoperating -10oC~70oC
Dimension W*H*D(mm) 214*108*365
Weight Kg 3.5